Analysis and Implementation of Kidney Stone Detection by Reaction Diffusion Level Set Segmentation Using Xilinx System Generator on FPGAReport as inadecuate




Analysis and Implementation of Kidney Stone Detection by Reaction Diffusion Level Set Segmentation Using Xilinx System Generator on FPGA - Download this document for free, or read online. Document in PDF available to download.

VLSI Design - Volume 2015 2015, Article ID 581961, 10 pages -

Research Article

Pondicherry Engineering College, Puducherry 605 014, India

Department of ECE, Pondicherry Engineering College, Puducherry 605 014, India

Received 20 October 2014; Revised 15 April 2015; Accepted 20 April 2015

Academic Editor: Mohamed Masmoudi

Copyright © 2015 Kalannagari Viswanath and Ramalingam Gunasundari. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Ultrasound imaging is one of the available imaging techniques used for diagnosis of kidney abnormalities, which may be like change in shape and position and swelling of limb; there are also other Kidney abnormalities such as formation of stones, cysts, blockage of urine, congenital anomalies, and cancerous cells. During surgical processes it is vital to recognize the true and precise location of kidney stone. The detection of kidney stones using ultrasound imaging is a highly challenging task as they are of low contrast and contain speckle noise. This challenge is overcome by employing suitable image processing techniques. The ultrasound image is first preprocessed to get rid of speckle noise using the image restoration process. The restored image is smoothened using Gabor filter and the subsequent image is enhanced by histogram equalization. The preprocessed image is achieved with level set segmentation to detect the stone region. Segmentation process is employed twice for getting better results; first to segment kidney portion and then to segment the stone portion, respectively. In this work, the level set segmentation uses two terms, namely, momentum and resilient propagation to detect the stone portion. After segmentation, the extracted region of the kidney stone is given to Symlets, Biorthogonal bio3.7, bio3.9, and bio4.4, and Daubechies lifting scheme wavelet subbands to extract energy levels. These energy levels provide evidence about presence of stone, by comparing them with that of the normal energy levels. They are trained by multilayer perceptron MLP and back propagation BP ANN to classify and its type of stone with an accuracy of 98.8%. The prosed work is designed and real time is implemented on both Filed Programmable Gate Array Vertex-2Pro FPGA using Xilinx System Generator XSG Verilog and Matlab 2012a.





Author: Kalannagari Viswanath and Ramalingam Gunasundari

Source: https://www.hindawi.com/