Correlation of Blood Lactate and Mixed Venous Oxygen Saturation in Off-Pump CABGReport as inadecuate




Correlation of Blood Lactate and Mixed Venous Oxygen Saturation in Off-Pump CABG - Download this document for free, or read online. Document in PDF available to download.

Aim: To evaluate the correlation of blood lactate and mixed venous oxygen saturation to predict outcome in off-pump coronary artery bypass grafting. Method: This is a randomized study including 30 patients. Blood lactate and mixed venous oxygen saturation were measured in 4 groups of patients—number of grafts, presence or absence of left main coronary artery disease, ejection fraction and serum creatinine. Blood samples were taken before induction, after grafting, on intensive care unit admission, 24 hours and 48 hours after surgery. The measured blood lactate and mixed venous oxygen saturation are compared to assess the outcomes in terms of duration of ventilation and intensive care unit stay. Results: The blood lactate and mixed venous oxygen saturation values increased post operatively but no statistically significant difference in three groups— number of grafts, left main coronary artery disease and ejection fraction. In serum creatinine group, the blood lactate value was found to be statistically significant after grafting in patients with creatinine



Author: Ganapathy Sambandam Kamalakkannan, Ranjith Karthekeyan, Mahesh Vakamudi, Sandeep Bangale, Rajeshkumar Kodali, Hemanand Nayagam, S

Source: http://www.scirp.org/



DOWNLOAD PDF