Wear intensity of diferent heat treated nodular cast ironsReport as inadecuate




Wear intensity of diferent heat treated nodular cast irons - Download this document for free, or read online. Document in PDF available to download.

Metallurgy, Vol.51 No.4 October 2012. -

In the paper we investigate the relationship between the wear intensity of two nodular cast irons and their heat treatment conditions. Disks tempered by austempering and isothermal procedure were used. The wear test was realized by using Pin and Disk tribometer. Measurement of the disks wear, after the contact for duration of 30 min, was done by the PQ meter. The quantity of the wear products in lubricant is determined by the PQ index. The best wear resistance posses the disk isothermally tempering with 30 minutes holding at 390 °C temperature.

nodular cast iron; wear; heat treatment



Author: D. Golubović - ; Faculty of Mechanical Engineering, East Sarajevo, Bosnia and Herzegovina P. Kovač - ; Faculty of Technical Sci

Source: http://hrcak.srce.hr/