Behaviour of a Composite Concrete-Trapezoidal Steel Plate Slab in FireReport as inadecuate




Behaviour of a Composite Concrete-Trapezoidal Steel Plate Slab in Fire - Download this document for free, or read online. Document in PDF available to download.

The present paper investigates fire resistance of a simply-supported composite concrete-trapezoidal steel sheet slab. The objective is to find out if a steel sheet, as a moisture diffusion barrier, may substantially effect the hydro-thermal situation in the concrete part of the cross-section. The numerical integration of the equations of a coupled hygro-thermal boundary-value problem Tenchev, R.T., Li, L.Y. and Purkiss, J.A. 2001 Num. Heat Transfer Part A, 397, 685-710, with and without considering the barrier, shows that the barrier does not really effect the magnitude and the development of temperatures over the cross-section, while there is a significant effect on the pattern of moisture transport and the magnitude of vapour pressure. Particularly high magnitudes of vapour pressure about 4.5 MPa were shown in cases where the steel sheet was considered in analyses, which indicates a possible micro damage of concrete in the web of the section, although spalling probably cannot take place due to the steel sheet cover. As the typical composite slab investigated here is not sufficiently fire resistant without any additional reinforcement bars placed in the web, further in-vestigations are directed to finding an optimal position and area of these bars. Following a simplified procedure given in EC2 Eurocode 2, Design of Concrete Structures, Part 1.2 2004 Structural fire design, European Committee for Standardization and assuming that the present composite slab is subject to the uniform traction , yields that placing one bar with the area 1.153 cm2 4 cm away from the edge suffices for the 60 min fire resistance of the slab.

KEYWORDS

Fire Analysis, Composite Structures, Heat and Mass Transfer

Cite this paper

T. Hozjan, M. Saje, I. Planinc, S. Srpčič and S. Bratina -Behaviour of a Composite Concrete-Trapezoidal Steel Plate Slab in Fire,- Engineering, Vol. 2 No. 8, 2010, pp. 594-601. doi: 10.4236-eng.2010.28076.





Author: Tomaž Hozjan, Miran Saje, Igor Planinc, Stanislav Srpčič, Sebastjan Bratina

Source: http://www.scirp.org/



DOWNLOAD PDF




Related documents