LED-Absorption-QEPAS Sensor for Biogas PlantsReport as inadecuate




LED-Absorption-QEPAS Sensor for Biogas Plants - Download this document for free, or read online. Document in PDF available to download.

1

Fraunhofer Heinrich Hertz Institute

2

Clausthal University of Technology, IEPT, Am Stollen 19B, Goslar 38640, Germany

3

Clausthal University of Technology, EFZN, Am Stollen 19A, Goslar 38640, Germany





*

Author to whom correspondence should be addressed.



Academic Editor: Vittorio M.N. Passaro

Abstract A new sensor for methane and carbon dioxide concentration measurements in biogas plants is presented. LEDs in the mid infrared spectral region are implemented as low cost light source. The combination of quartz-enhanced photoacoustic spectroscopy with an absorption path leads to a sensor setup suitable for the harsh application environment. The sensor system contains an electronics unit and the two gas sensors; it was designed to work as standalone device and was tested in a biogas plant for several weeks. Gas concentration dependent measurements show a precision better than 1% in a range between 40% and 60% target gas concentration for both sensors. Concentration dependent measurements with different background gases show a considerable decrease in cross sensitivity against the major components of biogas in direct comparison to common absorption based sensors. View Full-Text

Keywords: optical sensing; spectroscopy; photoacoustic; absorption; biogas optical sensing; spectroscopy; photoacoustic; absorption; biogas





Author: Michael Köhring 1,* , Stefan Böttger 1, Ulrike Willer 2,3 and Wolfgang Schade 1,2,3