Abstract Compared with the three-phase, two-split-capacitor active power filter 3P2C-APF, the three-phase, four-leg active power filter 3P4L-APF has been widely used in three-phase, four-wire grid utility for power quality control due to its numerous advantages, such as higher current output capability, particularly in phase N, lower current and easier voltage control on the DC-side. However, designing the grid-connecting interface, which is between the voltage source converter VSC and grid utility, is rather difficult due to the higher requirement for current ripple filtering in phase N, cross-coupling in four phases and lack of relevant design methodology and specification. In this paper, a four-branch LCL-type 4B-LCL grid-connecting interface is proposed for 3P4L-APF, which features better current ripple filtering performance without decreasing the current output capability in all phases. First, this paper describes the mathematical models of 4B-LCL in the fully-complex-vector form from the zero and non-zero sequence perspective, resulting in two independent and uniform equivalent circuits without cross coupling terms. Then, the 4B-LCL parameter design method based on the most comprehensive performance index is proposed, including three main stages as the specification: performance index requirement determination, fulfillment of that requirement, and verification. Finally, the validity and effectiveness of the proposed design are proven by the simulated and experimental results of a 3P4L-APF with 4B-LCL. View Full-Text

Keywords: three-phase four-leg 3P4L; four-branch LCL 4B-LCL; grid-connecting; active power filter APF; power quality PQ; pulse-width-modulated PWM converter three-phase four-leg 3P4L; four-branch LCL 4B-LCL; grid-connecting; active power filter APF; power quality PQ; pulse-width-modulated PWM converter





Author: Wu Cao * , Kangli Liu, Yongchao Ji, Yigang Wang and Jianfeng Zhao

Source: http://mdpi.com/



DOWNLOAD PDF




Related documents