J. Candelo ; O. Duarte ;Ingeniería e Investigación 2012, 32 2

Author: J. Montaña

Source: http://www.redalyc.org/


Teaser



Ingeniería e Investigación ISSN: 0120-5609 revii_bog@unal.edu.co Universidad Nacional de Colombia Colombia Montaña, J.; Candelo, J.; Duarte, O. Sands electrical parameters vary with frequency Ingeniería e Investigación, vol.
32, núm.
2, mayo-agosto, 2012, pp.
34-39 Universidad Nacional de Colombia Bogotá, Colombia Available in: http:--www.redalyc.org-articulo.oa?id=64323232007 How to cite Complete issue More information about this article Journals homepage in redalyc.org Scientific Information System Network of Scientific Journals from Latin America, the Caribbean, Spain and Portugal Non-profit academic project, developed under the open access initiative INGENIERÍA E INVESTIGACIÓN VOL.
32 No.
2, AUGUST 2012 (34-39) Sand’s electrical parameters vary with frequency Variación de los parámetros eléctricos de la arena con la frecuencia J.
Montaña1, J.
Candelo2, O.
Duarte3 ABSTRACT This paper presents the results of two types of test in one kind of sand to obtain resistivity and permittivity values for frequency ranging from Hz to MHz.
One test involved wave generation at specific frequencies and the other an impulse generator (continuous frequency spectrum).
Tests were made for three humidity values.
The results of both test revealed non-linear performance on test electrode surface.
Such non-linearity was modelled and eliminated to give the permittivity and resistivity values in frequency domain. Keywords: Soil measurement, impedance measurement, permittivity measurement, resistivity variation, impulse testing, transient response. RESUMEN Este artículo presenta los resultados de dos tipos de pruebas hechas a una clase de arena para obtener los valores de resistividad y permitividad eléctricas en el rango de los Hz hasta los MHz.
Una de las pruebas fue realizada a frecuencias específicas con un generador de señales, y la otra fue hecha con un generador de impulsos de tensión, con lo cual se trabajó un espectro continuo de frecuencias.
Las p...