A comparison of dual energy x- ray absorptiometry and two bioelectrical impedance analyzers to measure body fat percentage and fat-free mass index in a group of mexican young women Report as inadecuate




A comparison of dual energy x- ray absorptiometry and two bioelectrical impedance analyzers to measure body fat percentage and fat-free mass index in a group of mexican young women - Download this document for free, or read online. Document in PDF available to download.

Maria Esther Irigoyen-Camacho ; Raquel Huerta-Huerta ; Jaime Delgadillo-Velazquez ;Nutrición Hospitalaria 2014, 29 5

Author: Maria del Consuelo Velazquez-Alva

Source: http://www.redalyc.org/articulo.oa?id=309231670012


Teaser



Nutrición Hospitalaria ISSN: 0212-1611 info@nutriciónhospitalaria.com Grupo Aula Médica España Velazquez-Alva, Maria del Consuelo; Irigoyen-Camacho, Maria Esther; Huerta-Huerta, Raquel; Delgadillo-Velazquez, Jaime A comparison of dual energy X- ray absorptiometry and two bioelectrical impedance analyzers to measure body fat percentage and fat-free mass index in a group of Mexican young women Nutrición Hospitalaria, vol.
29, núm.
5, mayo-, 2014, pp.
1038-1046 Grupo Aula Médica Madrid, España Available in: http:--www.redalyc.org-articulo.oa?id=309231670012 How to cite Complete issue More information about this article Journals homepage in redalyc.org Scientific Information System Network of Scientific Journals from Latin America, the Caribbean, Spain and Portugal Non-profit academic project, developed under the open access initiative 12.
A COMPARISON_01.
Interacción 11-06-14 14:13 Página 1038 Nutr Hosp.
2014;29(5):1038-1046 ISSN 0212-1611 • CODEN NUHOEQ S.V.R.
318 Original - Obesidad A comparison of dual energy X- ray absorptiometry and two bioelectrical impedance analyzers to measure body fat percentage and fat-free mass index in a group of Mexican young women Maria del Consuelo Velazquez-Alva, Maria Esther Irigoyen-Camacho, Raquel Huerta-Huerta and Jaime Delgadillo-Velazquez Health Care Department.
Metropolitan Autonomous University Xochimilco.
Mexico City.
Mexico. Abstract Introduction: Studies of obesity require the estimation of fat mass (FM) and fat-free mass (FFM); therefore it is important to validate methods that evaluate these measurements. Objective: We sought to compare two different bioelectrical impedance analysis systems (BIAs) to estimate FM and FFM using dual-energy X-ray absorptiometry (DXA) as reference. Methods: We used a cross-sectional design.
We evaluated FM and FFM using DXA and two types of BIA equipment: a foot-foot system (FFS) and a hand-footsystem (HFS).
We conducted paired analysis (paired ttest).
We used Bland-Altm...