Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Evaluation of Equivalent Linearization MethodReport as inadecuate




Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Evaluation of Equivalent Linearization Method - Download this document for free, or read online. Document in PDF available to download.

Mathematical Problems in Engineering - Volume 2016 2016, Article ID 8934196, 17 pages -

Research ArticleDepartment of Civil Engineering, Design, Building and Environment, Second University of Naples, Via Roma 29, 81031 Aversa, Italy

Received 22 April 2016; Revised 21 July 2016; Accepted 17 October 2016

Academic Editor: Alessandro Palmeri

Copyright © 2016 Massimiliano Ferraioli and Alberto Mandara. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Although the most commonly used isolation systems exhibit nonlinear inelastic behaviour, the equivalent linear elastic analysis is commonly used in the design and assessment of seismic-isolated structures. The paper investigates if the linear elastic model is suitable for the analysis of a seismically isolated multiple building structure. To this aim, its computed responses were compared with those calculated by nonlinear dynamic analysis. A common base isolation plane connects the isolation bearings supporting the adjacent structures. In this situation, the conventional equivalent linear elastic analysis may have some problems of accuracy because this method is calibrated on single base-isolated structures. Moreover, the torsional characteristics of the combined system are significantly different from those of separate isolated buildings. A number of numerical simulations and parametric studies under earthquake excitations were performed. The accuracy of the dynamic response obtained by the equivalent linear elastic model was calculated by the magnitude of the error with respect to the corresponding response considering the nonlinear behaviour of the isolation system. The maximum displacements at the isolation level, the maximum interstorey drifts, and the peak absolute acceleration were selected as the most important response measures. The influence of mass eccentricity, torsion, and high-modes effects was finally investigated.





Author: Massimiliano Ferraioli and Alberto Mandara