Radioiodine Labeled Anti-MIF McAb: A Potential Agent for Inflammation ImagingReport as inadecuate




Radioiodine Labeled Anti-MIF McAb: A Potential Agent for Inflammation Imaging - Download this document for free, or read online. Document in PDF available to download.

Mediators of Inflammation - Volume 2007 2007, Article ID 50180, 5 pages

Research Article

Department of Nuclear Medicine, Qilu Hospital of Shandong University, Jinan 250012, China

Institute of Experimental Nuclear Medicine, School of Medicine, Shandong University, Jinan 250012, China

Received 21 June 2007; Accepted 22 August 2007

Copyright © 2007 Chao Zhang et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Macrophage migration inhibitory factor MIF is a proinflammatory cytokine that may play a role in the pathogenesis of inflammation. Radiolabeled anti-MIF McAb can be used to detect in vivo inflammatory changes. The objective of this study was to investigate in vivo biology of radioiodinated anti-MIF McAb using the inflammation model mice. Anti-MIF McAb was radioiodinated with Na

I by Iodogen method. Animal models were induced in the mice by intramuscular injection of S. aureus, E. coli, and turpentine oil. The biodistribution studies with radioiodinated anti-MIF McAb were performed on inflammation mice. The relationship between inflammatory lesions and anti-MIF McAb binding was investigated using the percent of injected dose per gram tissue % ID-g of tissue samples and whole-body autoradiography. The radioactivity of

I-anti-MIF McAb in the inflammatory tissue increased gradually for three inflammation models. The highest uptake was found in S. aureus group and the lowest was in E. coli group. The uptake in turpentine oil group was average. Whole-body autoradiography showed that all inflammation foci could be visualized clearly from 24 hours after injection, but 48 hours images were much clearer in accordance with the high T-NT ratio. These results demonstrate the ability of radioiodinated anti-MIF McAb to measure in vivo inflammatory events represented by high expression of MIF and suggests that radiolabeled anti-MIF McAb warrants further investigation as a potential inflammation-seeking agent for imaging to detect inflammatory disorders.





Author: Chao Zhang, Gui-hua Hou, Jian-kui Han, Jing Song, and Ting Liang

Source: https://www.hindawi.com/



DOWNLOAD PDF




Related documents