Analysis of the accuracy of shock-capturing in the steady quasi-1D Euler equationsReport as inadecuate




Analysis of the accuracy of shock-capturing in the steady quasi-1D Euler equations - Download this document for free, or read online. Document in PDF available to download.

Reference: M. Giles, (1995). Analysis of the accuracy of shock-capturing in the steady quasi-1D Euler equations. Unspecified.Citable link to this page:

 

Analysis of the accuracy of shock-capturing in the steady quasi-1D Euler equations

Abstract: Insight into the accuracy of steady shock-capturing CFD methods is obtained through analysis of a simple problem involving steady transonic flow in a quasi-1D diverging duct. It is proved that the discrete solution error on either side of the shock is $O(h^{n})$ where $n$ is the order of accuracy of the conservative finite volume discretisation. Furthermore, it is shown that provided that $n \ge 2$ then the error in approximating $\int p dx$ is $O(h^{2})$. This result is in contrast to the general belief that shocks in 2D and 3D Euler calculations lead to first order errors, which motivates much of the research into grid adaptation methods.

Bibliographic Details

Issue Date: 1995-02Identifiers

Urn: uuid:fe8daa03-348f-40e7-9f22-4091c2595c9b Item Description

Type: Technical Report;

Relationships





Author: M. Giles - - - - Bibliographic Details Issue Date: 1995-02 - Identifiers Urn: uuid:fe8daa03-348f-40e7-9f22-4091c2595c9b - - - Ite

Source: https://ora.ox.ac.uk/objects/uuid:fe8daa03-348f-40e7-9f22-4091c2595c9b